Specifications:
Limited warranty up to 15 years
Range ratio up to 200:1 (14:1 flow range ratio)
Measuring range differential pressure up to 2.48 bar (1000 inh2o), absolute pressure up to 250.00 bar (3626 psia), gauge pressure up to 250.00 bar (3626 psi)
Line sizes 50 to 2440 mm (2 to 96 in.)
Output differential pressure, static pressure, process temperature, scale variable, mass flow, volume flow, energy flow
Communication protocols 4-20 mA Hart?, WirelessHART?, foundation ™ field bus
316 stainless steel, alloy C-276
Basic diagnosis, circuit integrity, process intelligence, plug-in impulse tube
Certification through independent third party implementation of SIL 2 / 3 certification, NACE certification, hazardous location certification based on IEC 61508, please refer to the complete specifications for a complete list of certifications
Function:
With built-in flow calculation, full compensation mass flow can be reported directly
The patented T-shape sensor can establish a fixed shunt point to improve the differential pressure signal over a wider flow range
Advanced diagnostics to detect abnormal process conditions and electrical loop problems through comprehensive diagnostics
Callendar van Dusen sensor combination improves temperature measurement accuracy and achieves first-class flow calculation
Ultra for flow performance class optimizes flow measurement with reading accuracy of ± 0.04%
With T-shaped Annubar design, long-term pressure loss is minimal
Integrated heat pipe sensor, increase process temperature measurement, no need to insert additional pipe
All welded supermodule ™ Industry leading precision in design and application
After full configuration and leakage test, the flowmeter can be installed quickly after unpacking
The stagnant region of the sensor can reduce noise, reduce measurement error and avoid particle blockage
SIL 2 / 3 certification (via third party) based on IEC 61508 and fmeda data pre use certification for safe installation